Hunter 1-Station ICD Decoder
Hunter ICD-100 one-station decoder
The ICD-100 operates one irrigation valve station from a compatible Hunter two-wire controller. Its field-programmable address lets a station be assigned at the controller before installation or changed later with an ICD-HP handheld programmer.
Key details
- One station for a standard 24 V AC irrigation solenoid.
- For ACC2 Decoder and legacy ACC-99D Decoder controllers. Hunter also confirms ICD-100 compatibility with an I-Core DUAL system.
- Integrated surge protection and colour-coded two-wire connections.
- Waterproof DBRY-6 connectors included for two-wire path splices.
- Hunter's recommended maximum decoder-to-solenoid distance is approximately 45 m.
Selection note: Check the controller and decoder output module before ordering. This is an ICD-100, not the single-station DUAL-1 or EZ-1. Follow the system design for grounding and waterproof field connections.
Two-wire path: Hunter lists maximum runs of 3 km with 2 mm² ID1 cable or 4.5 km with 4 mm² ID2 cable for ICD systems. See the model-specific technical summary in the product gallery; check the full cable and grounding design for the site.
Couldn't load pickup availability